The vertical grab bar is only specified in the icc ansi a117 1 accessible and usable buildings and facilities.
Ada vertical grab bar.
8370 101 8370 102 8370 103 swing up grab bars.
Grab bars 1 1 4 o 1 1 2 o mounted at 33 above floor with 1 1 2 wall clearance.
However you will often see them while in a toilet room or in the accessible stall.
Grab bars shall be installed in a horizontal position 33 inches 840 mm minimum and 36 inches 915 mm maximum above the finish floor measured to the top of the gripping surface except that at water closets for children s use complying with 604 9 grab bars shall be installed in a horizontal position 18 inches 455 mm minimum and 27 inches 685 mm maximum above the finish floor measured to the top of the gripping surface.
The icc a117 1 standard for accessible and usable buildings and facilities which is referenced by the international building code requires an 18 min.
Grab bars need to be mounted lower for better leverage 33 36 840 915 mm high.
Two grab bars shall be installed on the back wall one located in accordance with 609 4 and other located 8 inches 205 mm minimum and 10 inches 255 mm maximum above the rim of the bathtub.
One revit file contains three bradley product numbers which cover all available lengths and tissue dispenser options.
Horizontal side wall grab bars need to be 42 1065 mm minimum length.
Dimensions for grab bars.
The ada standards do not require this grab bar but allow a second grab bar to be within the 12 clearance above the horizontal grab bar 609 3 if there is a separation of 1 min.
Home products washroom accessories toilet compartment accessories grab bars.
44 above the floor.
A a b b 36 max 915 mm 48 max 1220 mm.
14 from wall and 17 above floor with operable control at max.
In figure 29 b a 42 inch 1065 mm minimum length grab bar is required to the side of the water closet spaced 12 inches 305 mm maximum from the back wall and extending a minimum of 54 inches 1370 mm from the back wall at a height between 33 and 36 inches 840 915 mm.
The ada standards require horizontal grab bars on the rear wall and side wall of the water closet but it does not specify a vertical grab bar.
Toilets need to have horizontal bars behind and next to them and a vertical bar in front.
Urinal min.
Each grab bar shall be 24 inches 610 mm long minimum and shall be installed 24 inches 610 mm maximum from the head end wall and 12 inches 305 mm maximum from the control end wall.
8370 101 8370 102 8370 103 swing up grab bars.
Towel sanitary napkins and waste receptacles max.
Vertical grab bars are not yet covered in the ada guidelines however ansi specifies the dimensions shown in the diagram.
A summary of these requirements is below.
Grab bar code requirements are included in the standard ansii icc a117 1 of the international code council.
8170 158 8170 1581 grab bars product page.