A 42 inches 1065 mm minimum length grab bar is required on the side wall spaced a maximum of 12 inches 305 mm from the back wall and extending a minimum of 54 inches 1370 mm from the back wall at a height of 33 36 inches 840 915 mm.
Ada vertical grab bar toilet.
Grab bars 1 1 4 o 1 1 2 o mounted at 33 above floor with 1 1 2 wall clearance.
Toilet room fixtures and accessories.
Vertical grab bar at water closets.
The ada standards require horizontal grab bars on the rear wall and side wall of the water closet but it does not specify a vertical grab bar.
A a b b 36 max 915 mm 48 max 1220 mm.
However ansi allows for 6 mm projection in the allowed.
The ada standards do not require this grab bar but allow a second grab bar to be within the 12 clearance above the horizontal grab bar 609 3 if there is a separation of 1 min.
Dimensions for grab bars.
The icc a117 1 standard for accessible and usable buildings and facilities which is referenced by the international building code requires an 18 min.
Grab bars shall be installed in a horizontal position 33 inches 840 mm minimum and 36 inches 915 mm maximum above the finish floor measured to the top of the gripping surface except that at water closets for children s use complying with 604 9 grab bars shall be installed in a horizontal position 18 inches 455 mm minimum and 27 inches 685 mm maximum above the finish floor measured to the top of the gripping surface.
In showers and toilets the top of a horizontal grab bar must be 33 36 inches off the floor.
Recessed dispensers are allowed within the 12 305 mm space above and 1 38 mm space below and at the end of a grab bar for ada the recessed dispenser must be flush.
The bottom of a vertical bar in transfer showers must be 3 6 inches over the horizontal bar on the wall.
Towel sanitary napkins and waste receptacles max.
However you will often see them while in a toilet room or in the accessible stall.
Each grab bar shall be installed 15 inches 380 mm maximum from the head end wall and 12 inches 305 mm maximum from the control end wall.
Grab bars need to be mounted lower for better leverage 33 36 840 915 mm high.
The bar should be mounted at 33 36 above the floor.
Where the problem comes in is that installers frequently aim for one edge of this range and wind up a bit too low or high.
Water closet height min.
19 water closet flush control max.
A grab bar 24 inches 610 mm long minimum shall be installed on the control end wall at the front edge of the bathtub.
Grab bars are required in accessible toilet rooms.
Bathtubs without permanent seats.
The toilet paper dispenser shall be mounted below the grab bar at a minimum height of 19 inches 485 mm.
Horizontal side wall grab bars need to be 42 1065 mm minimum length.
Vertical grab bars are not yet covered in the ada guidelines however ansi specifies the dimensions shown in the diagram.