Clear width is 32 inches 815 mm minimum measured from the face of the door open 90 degrees to the face of the doorstop.
Ada toilet partition door width.
Doorways shall have a minimum clear opening of 32 in 815 mm with the door open 90 degrees measured between the face of the door and the opposite stop.
The minimum width of the stall is 60 inches 1525 mm.
A visual representation of these two can be found easily by reviewing figure 30 a for standard stalls and figure 30 b for alternative stalls.
Clearances are required at accessible elements fixtures and controls so that people with disabilities including those who use wheelchairs can approach and use them.
If a toilet compartment contains more than one plumbing fixture e g a lavatory it must comply as a toilet room 604 8.
If toilet stall approach is from the latch side of the stall door clearance between the door side of the stall and any obstruction may be reduced to a minimum of 42 in 1065 mm.
Compliance with this mandate requires all structurally practicable facilities constructed after january 26th 1992 to contain at least one fully accessible stall for disabled users as per.
An example of a single ada bathroom layout.
Toilet partitions and the americans with disabilities act ada restroom partitions are classified as either a standard stall or an alternative stall.
Horizontal grab bars must be mounted behind the toilet and on the nearest side wall or partition.
Figure 30 a standard stall.
For commercial bathrooms with multiple toilet stalls and handicap the rules change a little.
Stall width 60 minimum inside clear stall depth.
The location of the door is in front of the clear space and diagonal to the water closet with a maximum stile width of 4 inches 100 mm.
The toilet must be offset on the back wall with its centerline 18 from the nearest side wall or partition.
Can compartment door openings be located more than 4 from the side partition when the compartment width exceeds the 60 minimum.
The overall width should equal the sum of adding up each stall width.
Ada guide the americans with disabilities act ada is a mandate that prohibits discriminatory action against those who suffer from various disabilities.
Multiple toilet stall layouts.
The factory will determine pilaster sizes from the stall width and door width sizes that we give them see chart click on picture and then expand.
Refer to the illustration on page 2 for dimensions and more detailed information.
The centerline of the water closet is 18 inches 455 mm from the side wall.
Figure 30 a standard stall.