This knee clearance must be 29 inches 735 mm high at the front of the lavatory and no less than 27 inches 685 mm high at a point 8 inches 205 mm back.
Ada lavatory clearance from wall.
An accessible lavatory at least one in each bathroom must extend at least 17 inches from the back wall and have a clearance of at least 29 inches from the bottom of the sink apron to the finished floor.
The minimum knee clearance must be free of equipment or obstructions for a minimum of 8 inches 205 mm extending from the front edge of the lavatory back toward the wall.
Accessories such as toilet paper dispensers should be within.
A knee clearance of 24 inches 610 mm minimum above the finish floor or ground shall be permitted at lavatories and sinks used primarily by children 6 through 12 years where the rim or counter surface is 31 inches 785 mm maximum above the finish floor or ground.
Clearances around toilets and water closets wcs can be measured from the face of the fixture or from its center line and are used to best service the toilet user.
From the water closet centerline if the clearance at the water closet is at least 66 instead of 56 deep 604 3 2 ex.
Clearances are required at accessible elements fixtures and controls so that people with disabilities including those who use wheelchairs can approach and use them.
The standards also address maneuvering space for wheelchair turning.
Only one bowl in a multi bowl sink needs to offer minimum knee and toe clearances so these multi height lavatory systems combine an ada compliant sink with higher sinks.
A compliant lavatory is permitted on the rear wall 18 min.
Clearance reduced at curved or sloped walls recommendation.
The walls behind and surrounding the cabinetry are finished.
Consider solid surface lavatory systems with fully integrated sinks at various heights.
A minimum height is not specified for barriers demarcating areas with less than 80 of vertical clearance.
In both alternate stalls the grab bars along the sides of the water closets shall extend at least 54 inches 1370 mm from the back wall and shall have one end no farther than 12 inches 305 mm from the back wall.
This knee clearance must be 29 inches 735 mm high at the front of the lavatory and no less than 27 inches 685 mm high at a point 8 inches 205 mm back.
Minimum clearances between the face of the toilet fixture and the wall or nearest obstruction element are at least 24 61 cm but are recommended to be 36 91 cm.
Dwelling unit water closet and lavatory.
The lavatory must not be installed at heights greater than 34.
All other applicable requirements including clearances and turning space must be met.
This guide explains requirements in the ada standards for clear floor or ground space and turning space.