The bar must be 1 1 4 to 1 1 2 inches in diameter.
Ada bathtub requirements.
Clearance in front of bathtubs shall extend the length of the bathtub and shall be 30 inches 760 mm wide minimum.
Ada standards for accessible design can be downloaded from www ada.
A grab bar 24 inches 610 mm long minimum shall be installed on the control end wall at the front edge of the bathtub.
Or for answers to specific questions call the toll free ada information line at 800 514 0301 voice or 800 514 0383 tty.
On the bathtub wall surround the space with rails the person can support themselves with and hold on to.
Clear floor space at.
And the 2004 adaag at 36 cfr part 1191 appendices b and d.
State and local government facilities must follow the requirements of the 2010 standards including both the title ii regulations at.
In the few places where requirements between the two differ the requirements of 28 cfr 35 151 prevail.
An in tub seat or a seat at the head end of the tub.
Each grab bar shall be installed 15 inches 380 mm maximum from the head end wall and 12 inches 305 mm maximum from the control end wall.
Clear floor space at bathtubs.
Clearance around a water closet shall be 60 inches 1525 mm minimum measured perpendicular from the side wall and 56 inches 1420 mm minimum measured perpendicular from the rear wall.
Figure 604 3 1 size of clearance at water closets 604 3 2 overlap.
Clear floor space in front of bathtubs shall be as shown in fig.
Required compliance 213 plumbing and building codes address the number and type of bathing rooms and fixtures required for a facility.
In new construction access is required to all bathing rooms including those for employees.
Bathtubs shall comply with 607.
Grab bars must be installed between 34 and 38 inches above the floor and there must be a separation between the grab bar and the wall surface of at least 1 1 2 inches.
For more information for information about the ada including the revised 2010 ada regulations please visit the department s website www ada gov.
The ada standards on the other hand address access to bathing rooms where they are provided.
A permanent seat at the head end of the bathtub or a removable in tub seat.
An ada compliant grab bar handrail must be fully anchored and have a smooth surface that can be easily grabbed.
Accessible bathtubs shall comply with 4 20.
The optimal diameter is 1 to 1 inches while ada grab bars should be 34 to 38 inches above the floor.
Bathtubs without permanent seats.