Two grab bars shall be installed on the back wall one located in accordance with 609 4 and the other located 8 inches 205 mm minimum and 10 inches 255 mm maximum above the rim of the bathtub.
Ada bathroom grab bar heights.
The toilet paper dispenser shall be mounted below the grab bar at a minimum height of 19 inches 485 mm.
But i would strongly recommend to take into consideration the height and physical capabilities of the person you are installing these grab bars for.
In addition the grab bar heights for children are found in 609 4.
A grab bar 24 inches 610 mm long minimum shall be installed on the control end wall at the front edge of the bathtub.
A 42 inches 1065 mm minimum length grab bar is required on the side wall spaced a maximum of 12 inches 305 mm from the back wall and extending a minimum of 54 inches 1370 mm from the back wall at a height of 33 36 inches 840 915 mm.
Grab bars 1 1 4 o 1 1 2 o mounted at 33 above floor with 1 1 2 wall clearance.
Horizontal grab bars must be installed behind the toilet and on the nearest wall or partition whichever is closer.
If toilets and toilet compartments are meant to be used by children the standards provides suggestions and guidance in lieu of using the adult guidelines.
Each grab bar shall be installed 15 inches 380 mm maximum from the head end wall and 12 inches 305 mm maximum from the control end wall.
For horizontal grab bars the ada standards require a height between 33 and 36 inches from the finished floor of the bathroom shower or tub.
For 3 and 4 year olds bars should be 18 20 inches from the floor for 5 to 8 year olds bars should be 20 25 inches and for 9 to 12 year olds grab bars should be 25 27 inches.
It is helpful to use this range as a guide for placement but the most important part is selecting a height that feels comfortable and secure for the person using them.
Typically grab bars in the shower should be installed 33 to 36 inches from the floor of the bathroom this is according to ada americans with disabilities act standards.
A 42 inches 1065 mm minimum length grab bar is required on the side wall spaced a maximum of 12 inches 305 mm from the back wall and extending a minimum of 54 inches 1370 mm from the back wall at a height of 33 36 inches 840 915 mm.
Towel sanitary napkins and waste receptacles max.
Toilet seat heights must be 17 to 19 inches above the finished floor.
Each grab bar shall be installed 15 inches 380 mm maximum from the head end wall and 12 inches 305 mm maximum from the control end wall.
The guidelines for children s toilets are found in ada tas section 604 9.
Figure 607 4 1 grab bars for bathtubs with permanent seats.
14 from wall and 17 above floor with operable control at max.
The lever for flush control must be placed on the open side of the toilet with the clearest floor space and mounted no higher than 44 inches above the finished floor.